Models of Electrical Stations
Circuit Breaker (Q or CB) 22 kV
1




Rated Voltage 25.8 kV



Continuous Current 630A



Frequency: 50/60Hz



Rated shot time current 16 kA



Rated making current:



   + Asym: 16 kA



   + Peak: 41.6 kA



Number of Operation:



Mechanical 5,000 operations



Load Switching 400 operations



Reted power Frequency:



With stand Voltage Dry (1 min): 70 kV



With stand Voltage Wet (1 min): 60 kV





Disconnection Device (DS) 22 kV
1




3 x Single pole Disconnecting switches



Rated kV: 25.8 kV



Rated A: 600 A





Current Transformer (CT) 22 kV
1




3 x Oil Type Current Tranformer



Rated kV: 24 kV



Rated A: 10 VA



Range: 250 - 600 A/ 5A

Potential Tranformer (PT) 22 kV
1




3 x Oil Type Potential Tranformer



Rated kV: 24 kV



Rated V: 110 V



Rated VA: 25 VA

Zone Transformer 22/0.4 kV 160 kVA
1




Outdoor type, Mineral oil Immersed



Rated Frequency: 50Hz



Rated Capacity: 160 kVA



Rated Primary Voltage: 22 kV, 3 Phase 3 Wire



Rated Secondary Voltage: 416V, 3 Phase 4 Wire



Vector Group: DYN 11

Control Box Use for Relay in
1




Consist of KWH Meter in outdoor box IP 65



With control cable form CT., PT. included ground system

Pole 12 m
3
Electricity pole 12 m





Pole 8 m
2
Electricity pole 8 m

Lighting Arrester (LA) 22 kV
1




Type SA (GK)



Rated kV: 24 kV



Rated kA: 10 kA



According to IEC 60099-4

Electrical Practice Equipment
Load Center Phase 220 V, 12 locks
2




Load Center Consumer Unit



For 12 modules



1 phase, 2 wire, 240BV with ground bar



According to IEC 60439-1





Load Center Phase 380 V, 18 locks
3




Load Center Consumer unit



For 18 Modules



3 phase, 4 wire, 240/ 415 V with ground bar.



According to IEC 60439-1





Digital Ground Tester
3




Earth Resistance Tester are small, light weight and dust proof.



Measurement range 0-20/ 0-200/ 0-2000 ohm



Earth Voltage 0 - 200 VAC, 50 Hz



Overload Protection



Safety Standard IEC 61010-1





Mega Ohm Meter
2




Insulation tester combine a true-rms digital multimeter



 - Insulation test voltage 50V/ 100V/ 250V/ 500V and 1000V



 - Insulation test 0.01 MΩ to Z GΩ



 - Auto - discharge of capacitive voltage for added user protection



 - AC/DC voltage, DC miliVolts, AC/DC miliampes, Resistance, Continuity



 - Capacitance, Diode test, Temperature, Min/Max, Frequency

Digital Multi Tester
4
True - rms AC voltage and current for accurate measurements on non-linear signals.



AC/DC votalge: 600 V



AC/DC Current: 600 A (via jaw)



Resistane: 6000 ohm



Frequency: 500 Hz





Current Transformer
12
Rated current 50/5A, 1VA



Window size 30 x 20 mm



Rated voltage: 600 VAC



Operating Frequency 50/ 60Hz



Class 1.0



Case ABS Plastic Case





3 Phase Rotation Tester
4




 - Digital Phase indicator with open phase checker



 - Operational voltage 200 - 480 VAC



 - Time limit for continuous 200V : With in 60 minutes



 - Time limit for continuous 480V : With in 4 minutes



 - Frequency response 20 -400 Hz



 - With stand voltage 2200 V AC for 1 minute

Analog AC Ammeter Meter
4




Analog AC Ammeter moving iron type



Connect with CT measuring range 30/5A



Fron panel 96 x 96 mm

Electrical Drill (BOSS)
2




 - Heavy duty



 - Single phase rotary hamamer drill.230 V



 - Impact energy 0 - 3 J



 - Impact at nominal speed 0 -4000 1/min



 - Nominal rated input: 800 W. Tool chuck DSD plus



 - Drilling capacity into concrete with impact drills 4 - 26 mm



 - Drilling capacity into steel 13 mm



 - Drilling capacity into wood 30 mm



 - Max Drill diameter into masonry with kernel drill 68 mm



 - Comes with impact resistant plastic box. SDS max adapter, plat chisel, moil point chisel, hammer drill set, depth gauge and additional handle





Automatic Control Motor
PLC Module
4
 - Portable training kit



 - Power supply 100 -240 VAC



 - Maximum number I/O = 24 point



 - Output type: Relay



 - Integrated input: 14



 - Integrated output: 10



 - Interface cable PC to PLC





SENSOR Combine
2
 - Inductive proximity sensors or switches



 - Maximum operation Distance 5 mm



 - Supply voltage 10 VDC





Control Relay
10
 - Three-phase monitoring relay



 - Measuring range: 3 x 300 - 500 VAC



 - Rated Control supply Voltage (Us): 3 x 300 - 500 VAC



 - Output: 2 c/o (SPDT) contacts



 - Time Rang:



 - 200 ms start-up delay



 - 0s or 0.1 - 30 s tripping delay (ON/OFF)

Temperature Controller/ Digital
4
Temperature controller / Digital Temperature controller



 - Input Thermocouple Type: K, J, T, R, N, S, B and PT 100/ RTD.



 - Output type Relay



 - Contact 250 VAC / 3A and SSR Drive voltage 0 -12 VDC.



 - PID self tuning and ON/ OFF



 - Power supply 100 -240 VAC

Contactor
10
Three-phase main contactor



One auxilary contact NC (230 V, 50 Hz)



Coil Voltage 220 V, 50 Hz





Push Buttons Switch
15
Push button switch 1NO/NC



Diameter 22 mm



Voltage 220 VAC





Over Load Relay
5
Over Load relay uses with contactor



Type SN 20/ ST 20 5 (4-6) A





Circuit Breaker
5
3-pol C 16A - Miniature Circuit breaker (MCB)



According to DIN/VDE 0641/T11 for line safety Breaking Capacity / Contact rating 6 KVA single pol Triple Pole (3 Pole)





Digital timer Relay
5
Multi range delay timer:



 - Each Timing shall have 4 time ranges, selectable via DIP switch



 - Based on Microcontroller



 - Compact high performance on delay timer



 - Each timer shall have four time ranges, allowing switching to any of four set of time specification using a DIP switch on the timer body for reliable and easy operation.



 - When input voltage is applied, the timing cycle shall begins



 - At the end of the timed period the internal relay is energized.



 - Including standard 8-pin socket



 - Surface mounted timer converts to flush mounting style with optional adapter time switch, 1 pole, 16A, DIN rail 57 mm.





Pilot Lamps (3 Lamps)
20




Pilot lamp



Diameter 22 mm



Voltage 220 VAC

Three phase motor
2
Three phase asynchronous Motor (1 HP)



 - Three phase 380 - 415 Volt/ 50 Hz power supply



 - Output 0.5 HP/ 0.37 kW/ 4 pole



 - Speed 1395 rpm



 - Fan Cooled



 - Food Mounted (B3)



 - IP 55 enclosure

AC Inverter
3
Portable training kit



Power supply: 200 - 240 VAC



Starting torque: 150% or more



Output frequency: 0.2 - 200Hz



Communication: RS -485 standard or USB



Interface cable PC to inverter





Cable THAI YAZAKI THW 1*5 mm
6
THW 1.5 sqmm black/ 100 meter per roll





Electric induction Motor
4
Single phase asynchronous Motor (0.5 HP)

Foot Mounter

Single phase -220-240 Volt 50 Hz power supply



Output Power 0.5 HP/ 0.37 kW/ 4 Pole



Speed 1350 rpm



Fan cooled



Capacitor Start/ Capacitor Run



Foot Mounted (B3)



IP 55 Enclosure





Hand PLC Write
2
Industrial programming and maintenance tool



This unit can perform upload/ download and store upto 15 programs in its internal memory.



Power supply 5 VDC



Display LCD (with blacklight)



Keys: 35



Memory: Allowable number of writes: 100,000 times

Computer PC-compag/ HP
2
Processor: Core i3 - 3240 (3.4 GHz)



Graphic Card: HD Graphics/ share



Single DDR 3 4 GB/ 1600 MHz



Harddisk: 1 TB 7200 rpm



Monitor 20 inch LED